Honeywell Ignition Module Wiring Diagram

However problems can arise that cause the honeywell controller to malfunction.
Honeywell ignition module wiring diagram. Period ends the trial fopilot ignition ends and the control module goes into safely lockout. 7 for typical connections. The spark stops when it goes into lockout. Power off valve off.
A control module like honeywells s8610u controller attaches directly to the heating device providing ignition sequencing for an efficient heater. S89ef direct spark ignition control module application the honeywell s89ef direct spark ignition control modules control the ignition sequence and gas control operation in direct spark systems used primarily on gas fired atmospheric and power burners in residential furnaces and heating appliances. Check the wiring diagram furnished by the appli ance manufacturer if available for circuits differ. Q refer to the wiring diagram and pictures on the next page.
Q locate the components needed for this lab and mount them on the trainer. Dynamaxhs electrical diagram for honeywell sola ignition module 4 20ma models 399 800 drawing 99 0132 1 rev. The honeywell home trademark is used under license from honeywell international inc. Ignition module requires at least 02 a at 24 vac.
Use jumper wires to connect the components. To connect the d80b follow the wiring diagrams supplied with the vent damper or see fig. Q347 spark ignitor ignition cable q354 flame sensor procedure 1. Features l requires separate 120 vac spark.
Q instructor approves setup and wiring. Add the current draws of all other devices in the. Contains all the essential wiring diagrams across our range of heating controls. Intermittent pilot modules s8600 s8610 s8660 s8670.
Our wiring diagrams section details a selection of key wiring diagrams focused around typical sundial s and y plans. Use with a honeywell d80d or penn bas0 plug in vent damper motor figs. Connect remaining system components to the ignition module terminals as shown in the appropriate wiring diagram figs. Check the wiring diagram furnished by the appiiance manufacturer if available for.
S8610u universal intermittent pilot module application the s8610u universal replacement ignition module is designed to provide easy field replacement of a wide range of intermittent pilot ignition modules manufactured by honeywell robertshaw johnson and others. The s8610u module provides ignition sequence flame monitoring and. 03 dynamaxhs electrical diagram for honeywell sola ignition module models 80 299 drawing 99 0131 1 rev.